Citation:
Hassan Ali Zamani. Fabrication of a Ho3+-PVC membrane sensor based on N-phenyl-2-(thiophen-2-ylmethylene)hydrazinecarbothioamide for determination of holmium ions[J]. Chinese Chemical Letters,
;2011, 22(2): 201-204.
doi:
10.1016/j.cclet.2010.07.035
-
In this research, a new poly(vinyl chloride) (PVC) membrane sensor for Ho3+ ion based on N-phenyl-2-(thiophen-2-ylmethylene)hydrazinecarbothioamide (PHC) as an ionophore was prepared. This sensor demonstrated good selectivity and sensitivity towards the holmium ion in comparison with variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The effect of membrane composition and pH on the response properties of the electrode was investigated. In detail, the suggested sensor exhibited a Nernstian behavior (with a slope of 20.4 ±0.3 mV decade-1) in the range of 1.0×10-6 to 1.0×10-2 mol/L with a detection limit of 6.2×10-7 mol/L. The response time was relatively quick in the whole concentration range (~5 s). The sensor usage was found to be at least 10 weeks in a pH range of 3.3-10.9. It was successfully applied in determination of fluoride ions in mouth wash preparations.
-
Keywords:
- Sensor,
- PVC membrane,
- Ion-selective electrode,
- Potentiometiy
-
-
-
-
[1]
Xianghua Zeng , Weichen Meng , Xiaochun Han , Jiachen Yang , Kaiqi Wu , Fengxian Gao , Xiliang Luo . Highly stable and antifouling solid-contact ion-selective electrode for K+ detection in complex system based on multifunctional peptide and conductive MOF. Chinese Chemical Letters, 2025, 36(8): 110564-. doi: 10.1016/j.cclet.2024.110564
-
[2]
Xiangshuai Li , Jian Zhao , Li Luo , Zhuohao Jiao , Ying Shi , Shengli Hou , Bin Zhao . Visual and portable detection of metronidazole realized by metal-organic framework flexible sensor and smartphone scanning. Chinese Chemical Letters, 2024, 35(10): 109407-. doi: 10.1016/j.cclet.2023.109407
-
[3]
Erzhuo Cheng , Yunyi Li , Wei Yuan , Wei Gong , Yanjun Cai , Yuan Gu , Yong Jiang , Yu Chen , Jingxi Zhang , Guangquan Mo , Bin Yang . Galvanostatic method assembled ZIFs nanostructure as novel nanozyme for the glucose oxidation and biosensing. Chinese Chemical Letters, 2024, 35(9): 109386-. doi: 10.1016/j.cclet.2023.109386
-
[4]
Guangying Wang , Qinglong Qiao , Wenhao Jia , Yiyan Ruan , Kai An , Wenchao Jiang , Xuelian Zhou , Zhaochao Xu . Adaptive emission profile of transformable fluorescent probes as fingerprints: A typical application in distinguishing different surfactants. Chinese Chemical Letters, 2025, 36(5): 110130-. doi: 10.1016/j.cclet.2024.110130
-
[5]
Haoquan Huang , Haiting Chen , Xinran Dong , Yanbin Xu , Anlian Huang , Qiaoyi Cen , Huairou Zhu , Guosheng Chen , Wei Yi , Siming Huang , Gangfeng Ouyang . Site-specific surface amination strategy facilitates biomimetic encapsulation of enzymes within hydrogen-bonded organic framework. Chinese Chemical Letters, 2025, 36(9): 111223-. doi: 10.1016/j.cclet.2025.111223
-
[6]
Tianle Cao , Ni Yan , Yawen Li , Xinyi Zhang , Yue Zhu , Naiyao Li , Zengrong Wang , Gang He . D-A-D-A-D conjugated pyrenoviologens for electrochromism, electrofluorochromism, and detection of picric acid. Chinese Chemical Letters, 2025, 36(10): 111021-. doi: 10.1016/j.cclet.2025.111021
-
[7]
Chong Wang , Hao Xie , Rulan Xia , Xuewei Liao , Jin Wang , Huajun Yang , Chen Wang . Nanofluidic ion rectification sensor for enantioselective recognition and detection. Chinese Chemical Letters, 2025, 36(8): 110642-. doi: 10.1016/j.cclet.2024.110642
-
[8]
Fangbing Wang , Qiankun Zeng , Jing Ren , Min Zhang , Guoyue Shi . A membrane-based plasma separator coupled with ratiometric fluorescent sensor for biochemical analysis in whole blood. Chinese Chemical Letters, 2025, 36(7): 110494-. doi: 10.1016/j.cclet.2024.110494
-
[9]
Pengcheng Yan , Peng Wang , Jing Huang , Zhao Mo , Li Xu , Yun Chen , Yu Zhang , Zhichong Qi , Hui Xu , Henan Li . Engineering Multiple Optimization Strategy on Bismuth Oxyhalide Photoactive Materials for Efficient Photoelectrochemical Applications. Acta Physico-Chimica Sinica, 2025, 41(2): 100014-0. doi: 10.3866/PKU.WHXB202309047
-
[10]
Huakang Zong , Xinyue Li , Yanlin Zhang , Faxun Wang , Xingxing Yu , Guotao Duan , Yuanyuan Luo . Pt/Ti3C2 electrode material used for H2S sensor with low detection limit and high stability. Chinese Chemical Letters, 2025, 36(5): 110195-. doi: 10.1016/j.cclet.2024.110195
-
[11]
Shuangying Li , Qingxiang Zhou , Zhi Li , Menghua Liu , Yanhui Li . Sensitive measurement of silver ions in environmental water samples integrating magnetic ion-imprinted solid phase extraction and carbon dot fluorescent sensor. Chinese Chemical Letters, 2024, 35(5): 108693-. doi: 10.1016/j.cclet.2023.108693
-
[12]
Siqi Sun , Cheng Zhao , Zhaohuan Zhang , Ding Wang , Xinru Yin , Jingting Han , Jinlei Wei , Yong Zhao , Yongheng Zhu . Highly selective QCM sensor based on functionalized hierarchical hollow TiO2 nanospheres for detecting ppb-level 3-hydroxy-2-butanone biomarker at room temperature. Chinese Chemical Letters, 2025, 36(5): 109939-. doi: 10.1016/j.cclet.2024.109939
-
[13]
Xueling Yu , Lixing Fu , Tong Wang , Zhixin Liu , Na Niu , Ligang Chen . Multivariate chemical analysis: From sensors to sensor arrays. Chinese Chemical Letters, 2024, 35(7): 109167-. doi: 10.1016/j.cclet.2023.109167
-
[14]
Lili Zhang , Hui Gao , Gong Zhang , Yuning Dong , Kai Huang , Zifan Pang , Tuo Wang , Chunlei Pei , Peng Zhang , Jinlong Gong . Cross-section design of the flow channels in membrane electrode assembly electrolyzer for CO2 reduction reaction through numerical simulations. Chinese Chemical Letters, 2025, 36(1): 110204-. doi: 10.1016/j.cclet.2024.110204
-
[15]
Tian Cao , Xuyin Ding , Qiwen Peng , Min Zhang , Guoyue Shi . Intelligent laser-induced graphene sensor for multiplex probing catechol isomers. Chinese Chemical Letters, 2024, 35(7): 109238-. doi: 10.1016/j.cclet.2023.109238
-
[16]
Neng Shi , Haonan Jia , Jixiang Zhang , Pengyu Lu , Chenglong Cai , Yixin Zhang , Liqiang Zhang , Nongyue He , Weiran Zhu , Yan Cai , Zhangqi Feng , Ting Wang . Accurate expression of neck motion signal by piezoelectric sensor data analysis. Chinese Chemical Letters, 2024, 35(9): 109302-. doi: 10.1016/j.cclet.2023.109302
-
[17]
Chen-Xin Wang , Guang-Lei Li , Yu Hang , Dan-Feng Lu , Jian-Qi Ye , Hao Su , Bing Hou , Tao Suo , Dan Wen . Shock-resistant wearable pH sensor based on tungsten oxide aerogel. Chinese Chemical Letters, 2025, 36(7): 110502-. doi: 10.1016/j.cclet.2024.110502
-
[18]
Qiang-Qiang Jia , Jia-Qi Luo , Zhi-Yu Xue , Jing-Song Tang , Wen-Qiang Qiu , Chang-Feng Wang , Zhi-Xu Zhang , Hai-Feng Lu , Yi Zhang , Da-Wei Fu . Enhanced output power density of PVDF/LM composite for piezoelectric sensor. Chinese Chemical Letters, 2025, 36(11): 110471-. doi: 10.1016/j.cclet.2024.110471
-
[19]
Ying Chen , Li Li , Junyao Zhang , Tongrui Sun , Xuan Zhang , Shiqi Zhang , Jia Huang , Yidong Zou . Tailored ionically conductive graphene oxide-encased metal ions for ultrasensitive cadaverine sensor. Chinese Chemical Letters, 2024, 35(8): 109102-. doi: 10.1016/j.cclet.2023.109102
-
[20]
Ting WANG , Peipei ZHANG , Shuqin LIU , Ruihong WANG , Jianjun ZHANG . A Bi-CP-based solid-state thin-film sensor: Preparation and luminescence sensing for bioamine vapors. Chinese Journal of Inorganic Chemistry, 2024, 40(8): 1615-1621. doi: 10.11862/CJIC.20240134
-
[1]
Metrics
- PDF Downloads(0)
- Abstract views(1161)
- HTML views(22)
Login In