Determination of urinary 8-hydroxy-2'-deoxyguanosine by capillary electrophoresis with molecularly imprinted monolith in-tube solid phase microextraction

Shao Wen Zhang Cun Jie Zou Nan Luo Qian Feng Weng Ling Shuang Cai Cai Ying Wu Jun Xing

引用本文: Shao Wen Zhang,  Cun Jie Zou,  Nan Luo,  Qian Feng Weng,  Ling Shuang Cai,  Cai Ying Wu,  Jun Xing. Determination of urinary 8-hydroxy-2'-deoxyguanosine by capillary electrophoresis with molecularly imprinted monolith in-tube solid phase microextraction[J]. Chinese Chemical Letters, 2010, 21(1): 85-88. doi: 10.1016/j.cclet.2009.08.010 shu
Citation:  Shao Wen Zhang,  Cun Jie Zou,  Nan Luo,  Qian Feng Weng,  Ling Shuang Cai,  Cai Ying Wu,  Jun Xing. Determination of urinary 8-hydroxy-2'-deoxyguanosine by capillary electrophoresis with molecularly imprinted monolith in-tube solid phase microextraction[J]. Chinese Chemical Letters, 2010, 21(1): 85-88. doi: 10.1016/j.cclet.2009.08.010 shu

Determination of urinary 8-hydroxy-2'-deoxyguanosine by capillary electrophoresis with molecularly imprinted monolith in-tube solid phase microextraction

  • 基金项目:

    We gratefully acknowledge the support of the National Natural Science Foundation of China (No. 20575051).

摘要: Urinary 8-hydroxy-2'-deoxyguanosine (8-OHdG) is an excellent marker of oxidative DNA damage. In this study, employing guanosine as dummy template a novel molecularly imprinted (MIP) monolithic capillary column had been synthesized, and that was used as medium of in-tube solid phase microextraction (SPME). Coupled with capillary electrophoresis-electrochemical detection (CE-ECD), the system of extraction and detection of 8-OHdG in urinary sample had been developed. Because of its greater phase ratio combined with convective mass transfer and inherent selectivity, the MIP monolithic column exhibited high extraction efficiency on target analyte with the limit of detection (LOD) and quantity (LOQ) reached 2.6 nmol/L (S/N=3) and 8.6nmol/L (S/N=10), respectively. The linear range was from 10 nmol/L to 1.5μ-mol/L (r=0.9999) with relative standard deviation (RSD) 3.7% for peak current, and 0.5% for migration time, and the average recovery of spiked 20-200 nmol/L 8-OHdG was 85%±3.5% (n=6). This highly sensitive method was applied to analysis of 8-OHdG in urinary samples from healthy volunteers, coking plant workers and lung cancer patients.