引用本文:
Fuai Hu, Yanru Yin, Yang Li, Feifei Guo, Jianhui Liu, Zeliang Gao. Super internal electrostatic field effect on self-powered X-ray detector in ferroelectric Pb(Mg1/3Nb2/3)O3-PbTiO3 single crystal[J]. Chinese Journal of Structural Chemistry,
2026, 45(5): 100863.
doi:
10.1016/j.cjsc.2025.100863
Citation: Fuai Hu, Yanru Yin, Yang Li, Feifei Guo, Jianhui Liu, Zeliang Gao. Super internal electrostatic field effect on self-powered X-ray detector in ferroelectric Pb(Mg1/3Nb2/3)O3-PbTiO3 single crystal[J]. Chinese Journal of Structural Chemistry, 2026, 45(5): 100863. doi: 10.1016/j.cjsc.2025.100863
Citation: Fuai Hu, Yanru Yin, Yang Li, Feifei Guo, Jianhui Liu, Zeliang Gao. Super internal electrostatic field effect on self-powered X-ray detector in ferroelectric Pb(Mg1/3Nb2/3)O3-PbTiO3 single crystal[J]. Chinese Journal of Structural Chemistry, 2026, 45(5): 100863. doi: 10.1016/j.cjsc.2025.100863
Super internal electrostatic field effect on self-powered X-ray detector in ferroelectric Pb(Mg1/3Nb2/3)O3-PbTiO3 single crystal
摘要:
Self-powered X-ray detectors that combine high sensitivity with low detection limits have emerged as a critical focus in radiation detection research. This work pioneers the application of lead magnesium niobate-lead titanate (PMN-PT) single crystal, renowned for its piezoelectric properties, as a material in self-powered X-ray detectors. Due to its super internal electrostatic field, the PMN-PT single crystal self-powered detector exhibits a sensitivity of 346 μC Gyair-1 cm-2 and a detection limit of 0.43 nGyair s-1 under 40 keV X-rays, which is 17 times and 0.008% as those of the commercial α-Se detector, respectively. Notably, the detector maintains a high sensitivity of 157 μC Gyair-1 cm-2 even under hard 120 keV, surpassing the performance of most reported perovskite self-powered detectors. Furthermore, the detector exhibits a significantly reduced baseline drift (∼1.0 pA) and excellent operational stability in self-powered mode. This study conclusively demonstrates that polar piezoelectric crystals, which incorporate heavy metal elements, are highly promising candidates for developing high-performance self-powered X-ray detectors.
English
Super internal electrostatic field effect on self-powered X-ray detector in ferroelectric Pb(Mg1/3Nb2/3)O3-PbTiO3 single crystal
Abstract:
Self-powered X-ray detectors that combine high sensitivity with low detection limits have emerged as a critical focus in radiation detection research. This work pioneers the application of lead magnesium niobate-lead titanate (PMN-PT) single crystal, renowned for its piezoelectric properties, as a material in self-powered X-ray detectors. Due to its super internal electrostatic field, the PMN-PT single crystal self-powered detector exhibits a sensitivity of 346 μC Gyair-1 cm-2 and a detection limit of 0.43 nGyair s-1 under 40 keV X-rays, which is 17 times and 0.008% as those of the commercial α-Se detector, respectively. Notably, the detector maintains a high sensitivity of 157 μC Gyair-1 cm-2 even under hard 120 keV, surpassing the performance of most reported perovskite self-powered detectors. Furthermore, the detector exhibits a significantly reduced baseline drift (∼1.0 pA) and excellent operational stability in self-powered mode. This study conclusively demonstrates that polar piezoelectric crystals, which incorporate heavy metal elements, are highly promising candidates for developing high-performance self-powered X-ray detectors.
扫一扫看文章
计量
- PDF下载量: 0
- 文章访问数: 425
- HTML全文浏览量: 15

下载: